N_Port-ID virtualization or NPIV for short is an extension of the FC standard and allows more than one N_Port to log into the fabric using the same physical FC port. In principle, this option has always existed, but only in connection with FC Arbitrated Loop (FC-AL) and fabrics. With NPIV, multiple client LPARs can share a physical FC port. Each client has its own unique N_Port.
Figure 7.12 shows the situation with 2 virtual FC client adapters. Each of the client adapters has a unique WWPN. The WWPN is assigned by PowerVM when the virtual FC client adapter is created (in order to be able to support live partition mobility, 2 WWPNs are always assigned, whereby only one of the two WWPNs is active). Each virtual FC client adapter requires a partner adapter on a virtual I/O server, the virtual FC server adapter (or vfchost). One of the physical FC ports must be assigned to the virtual FC server adapter on the virtual I/O server. If the client LPAR is active, the virtual FC server adapter logs into the fabric (FDISC) and is assigned a unique N_Port ID. In the figure it is the 8c8268 for the blue adapter and the 8c8262 for the red adapter. Then the blue adapter registers its client WWPN (here c0:50:76:07:12:cd:00:16) with the simple name server (SNS) of the fabric (PLOGI). The red adapter does the same for its client WWPN (here c0:50:76:07:12:cd:00:09). Both virtual FC client adapters then have an N_Port with a unique 24-bit ID and can thus communicate with other N_Ports in the fabric.